PosiTector® RTR H
Electronic Surface Profile Gage for Blasted Steel and Textured Coatings
Digital spring micrometers measure and record surface profile parameters using Testex Press-O-Film™ replica tape—producing a more accurate peak-to-valley height measurement.
Ready to measure—no calibration adjustment required for most applications
NEW Larger 2.8" impact resistant color touchscreen with redesigned keypad for quick menu navigation
NEW Weatherproof, dustproof, and water-resistant—IP65-rated enclosure
PosiTector interchangeable platform—attach any PosiTector probe to a single gage body
USB, WiFi, and Bluetooth connectivity to PosiSoft PC, Mac, and Smartphone software
Certificate of Calibration showing traceability to PTB included (Long Form)
Conforms to ASTM D4417, ISO 8503-5, NACE RP287, SSPC-PA 17, SSPC-SP5, SP6, SP10, SP11-87T, and others
Simple
Measures peak height (HL)
Automatically subtracts the 50.8 μm (2 mils) incompressible film from all readings
Minimizes inspector workload by reducing the number of replicas needed to ensure accuracy
NEW Larger 2.8" impact resistant color touchscreen with redesigned keypad for quick menu navigation
NEW On-gage help explains menu items at the touch of a button
RESET feature instantly restores factory settings
Durable
NEW Weatherproof, dustproof, and water-resistant—IP65-rated enclosure
Rugged indoor/outdoor instrument—ideal for field or shop use
NEW Ergonomic design with durable rubberized grip
Shock-absorbing, protective rubber holster for added impact resistance
Two year warranty on gage body AND probe
Accurate
Produces a more accurate peak-to-valley height measurement. See linearized peak height (HL)
Certificate of Calibration showing traceability to PTB included (Long Form)
Conforms to national and international standards including ISO 8503-5, ASTM D4417 Method C, NACE RP0287 and SSPC-PA17
Versatile
PosiTector body accepts all PosiTector RTR, SPG, 6000, 200, DPM, IRT, SST, SHD, BHI, and UTG probes easily converting from a surface profile gage to a coating thickness gage, dew point meter, soluble salt tester, hardness tester, or ultrasonic wall thickness gage
Mils/Microns switchable
Selectable display languages
NEW Auto rotating display with Flip Lock
Standard Models
Includes ALL features as shown on left plus...
NEW Storage of 1,000 readings per probe—stored readings can be viewed or downloaded
Powerful
Statistics mode continually displays/updates average, standard deviation, min/max, and number of readings while measuring
NEW Screen Capture—save 100 screen images for record keeping and review
NEW Instant-on feature quickly powers up the gage if recently powered down
NEW Up to 30% longer battery life
USB port for fast, simple connection to a PC and to supply continuous power. USB cable included
PosiSoft USB Drive—stored readings and graphs can be accessed using universal PC/Mac web browsers or file explorers. No software required.
Every stored measurement is date and time stamped
Software Solutions for viewing, analyzing & reporting data
Software Updates via web keep your gage current
LFC is the authorized distributor for DeFelsko in Singapore and Indonesia. Contact us to purchase the PosiTector RTR H or any other DeFelsko products.
How to use the PosiTector RTR H?
Step 1: Preparation of both the surface to be tested and the PosiTector RTR H are necessary before performing the test.
To prepare surface:
Use cleaning putty to remove dust, debris, or residual blast media from the measurement site by firmly pressing the putty onto surface to be tested using your fingers and remove
To prepare the PosiTector RTR H:
Clean anvils using included cleaning card. Swipe card through opening a few times while firmly pressing both probe buttons to remove dust
Zero probe and verify accuracy with included shim
Ensure correct grade of replica tape is displayed in upper left hand corner of LCD
Step 2: Burnish the Testex Press-O-Film™ replica tape onto the steel surface to form an impression/reverse replica.
Testex Press-O-Film™ replica tape consists of a layer of compressible foam affixed to an incompressible polyester film of highly uniform thickness. When pressed against a roughened steel surface, the foam forms an impression, or reverse replica, of the surface.
Select appropriate grade of replica tape based on target profile
Pull a single adhesive-backed replica tape free of its release paper and apply to blasted surface
Firmly compress replica film using the rounded end of the included stainless steel burnishing tool. Apply sufficient pressure in a circular and x-y rubbing motion for 30-60 seconds to fully compress all parts of the film. In general, too much compression is safer than too little.
When complete, remove replica tape from surface
Step 3: Measure the Tape with the PosiTector RTR H
Placing the compressed tape (replica) into the PosiTector RTR H gives a measure of the average maximum peak-to-valley height of the surface roughness profile.
Insert the burnished replica tape into the measurement opening. Ensure the tape is properly positioned so that the burnished region is centered within the opening in the probe with the adhesive (sticky) side down.
To position the tape, move the Testex™ Press-O-Film™ replica tape to the back of the probe and align the two dots (printed on replica tape) with arrows on both sides of the measurement opening.
Once positioned, firmly press both probe buttons simultaneously and hold until the PosiTector RTR H beeps and the measurement is displayed.
The gage automatically subtracts the thickness of the polyester substrate from all measurements.
PosiTector® RTR H
Electronic Surface Profile Gage for Blasted Steel and Textured Coatings
Digital spring micrometers measure and record surface profile parameters using Testex Press-O-Film™ replica tape—producing a more accurate peak-to-valley height measurement.
Ready to measure—no calibration adjustment required for most applications
NEW Larger 2.8" impact resistant color touchscreen with redesigned keypad for quick menu navigation
NEW Weatherproof, dustproof, and water-resistant—IP65-rated enclosure
PosiTector interchangeable platform—attach any PosiTector probe to a single gage body
USB, WiFi, and Bluetooth connectivity to PosiSoft PC, Mac, and Smartphone software
Certificate of Calibration showing traceability to PTB included (Long Form)
Conforms to ASTM D4417, ISO 8503-5, NACE RP287, SSPC-PA 17, SSPC-SP5, SP6, SP10, SP11-87T, and others
Simple
Measures peak height (HL)
Automatically subtracts the 50.8 μm (2 mils) incompressible film from all readings
Minimizes inspector workload by reducing the number of replicas needed to ensure accuracy
NEW Larger 2.8" impact resistant color touchscreen with redesigned keypad for quick menu navigation
NEW On-gage help explains menu items at the touch of a button
RESET feature instantly restores factory settings
Durable
NEW Weatherproof, dustproof, and water-resistant—IP65-rated enclosure
Rugged indoor/outdoor instrument—ideal for field or shop use
NEW Ergonomic design with durable rubberized grip
Shock-absorbing, protective rubber holster for added impact resistance
Two year warranty on gage body AND probe
Accurate
Produces a more accurate peak-to-valley height measurement. See linearized peak height (HL)
Certificate of Calibration showing traceability to PTB included (Long Form)
Conforms to national and international standards including ISO 8503-5, ASTM D4417 Method C, NACE RP0287 and SSPC-PA17
Versatile
PosiTector body accepts all PosiTector RTR, SPG, 6000, 200, DPM, IRT, SST, SHD, BHI, and UTG probes easily converting from a surface profile gage to a coating thickness gage, dew point meter, soluble salt tester, hardness tester, or ultrasonic wall thickness gage
Mils/Microns switchable
Selectable display languages
NEW Auto rotating display with Flip Lock
Standard Models
Includes ALL features as shown on left plus...
NEW Storage of 1,000 readings per probe—stored readings can be viewed or downloaded
Powerful
Statistics mode continually displays/updates average, standard deviation, min/max, and number of readings while measuring
NEW Screen Capture—save 100 screen images for record keeping and review
NEW Instant-on feature quickly powers up the gage if recently powered down
NEW Up to 30% longer battery life
USB port for fast, simple connection to a PC and to supply continuous power. USB cable included
PosiSoft USB Drive—stored readings and graphs can be accessed using universal PC/Mac web browsers or file explorers. No software required.
Every stored measurement is date and time stamped
Software Solutions for viewing, analyzing & reporting data
Software Updates via web keep your gage current
LFC is the authorized distributor for DeFelsko in Singapore and Indonesia. Contact us to purchase the PosiTector RTR H or any other DeFelsko products.
How to use the PosiTector RTR H?
Step 1: Preparation of both the surface to be tested and the PosiTector RTR H are necessary before performing the test.
To prepare surface:
Use cleaning putty to remove dust, debris, or residual blast media from the measurement site by firmly pressing the putty onto surface to be tested using your fingers and remove
To prepare the PosiTector RTR H:
Clean anvils using included cleaning card. Swipe card through opening a few times while firmly pressing both probe buttons to remove dust
Zero probe and verify accuracy with included shim
Ensure correct grade of replica tape is displayed in upper left hand corner of LCD
Step 2: Burnish the Testex Press-O-Film™ replica tape onto the steel surface to form an impression/reverse replica.
Testex Press-O-Film™ replica tape consists of a layer of compressible foam affixed to an incompressible polyester film of highly uniform thickness. When pressed against a roughened steel surface, the foam forms an impression, or reverse replica, of the surface.
Select appropriate grade of replica tape based on target profile
Pull a single adhesive-backed replica tape free of its release paper and apply to blasted surface
Firmly compress replica film using the rounded end of the included stainless steel burnishing tool. Apply sufficient pressure in a circular and x-y rubbing motion for 30-60 seconds to fully compress all parts of the film. In general, too much compression is safer than too little.
When complete, remove replica tape from surface
Step 3: Measure the Tape with the PosiTector RTR H
Placing the compressed tape (replica) into the PosiTector RTR H gives a measure of the average maximum peak-to-valley height of the surface roughness profile.
Insert the burnished replica tape into the measurement opening. Ensure the tape is properly positioned so that the burnished region is centered within the opening in the probe with the adhesive (sticky) side down.
To position the tape, move the Testex™ Press-O-Film™ replica tape to the back of the probe and align the two dots (printed on replica tape) with arrows on both sides of the measurement opening.
Once positioned, firmly press both probe buttons simultaneously and hold until the PosiTector RTR H beeps and the measurement is displayed.
The gage automatically subtracts the thickness of the polyester substrate from all measurements.
TECHNICAL SPECIFICATION
DeFelsko Replica Tape Reader PosiTector RTR H Ordering Guide:
Standard Model
RTRH1
Advanced Model
RTRH3
Probe Only
PRBRTRH
DeFelsko PosiTector RTR H Technical Specifications:
RTR H1
RTR H3
PEAK HEIGHT (HL) MEASUREMENT RANGE
20 to 115 μm (0.8 to 4.5 mils)
20 to 115 μm (0.8 to 4.5 mils)
PEAK HEIGHT (HL) ACCURACY
± 5 μm (± 0.2 mils)
± 5 μm (± 0.2 mils)
PEAK HEIGHT (HL) RESOLUTION
1 μm (0.2 mils)
1 μm (0.2 mils)
ANVIL DIAMETER
Ø6.3 mm (Ø0.25 inch)
Ø6.3 mm (Ø0.25 inch)
ANVIL PRESSURE
1.1 Newtons (110 gram-force)
1.1 Newtons (110 gram-force)
Request a Quote
Request A Quote
Please complete the below form to receive further information.
DeFelsko Replica Tape Reader PosiTector RTR H
Product description:
PosiTector® RTR H
Electronic Surface Profile Gage for Blasted Steel and Textured Coatings
Digital spring micrometers measure and record surface profile parameters using Testex Press-O-Film™ replica tape—producing a more accurate peak-to-valley height measurement.
Ready to measure—no calibration adjustment required for most applications
NEW Larger 2.8" impact resistant color touchscreen with redesigned keypad for quick menu navigation
NEW Weatherproof, dustproof, and water-resistant—IP65-rated enclosure
PosiTector interchangeable platform—attach any PosiTector probe to a single gage body
USB, WiFi, and Bluetooth connectivity to PosiSoft PC, Mac, and Smartphone software
Certificate of Calibration showing traceability to PTB included (Long Form)
Conforms to ASTM D4417, ISO 8503-5, NACE RP287, SSPC-PA 17, SSPC-SP5, SP6, SP10, SP11-87T, and others
Simple
Measures peak height (HL)
Automatically subtracts the 50.8 μm (2 mils) incompressible film from all readings
Minimizes inspector workload by reducing the number of replicas needed to ensure accuracy
NEW Larger 2.8" impact resistant color touchscreen with redesigned keypad for quick menu navigation
NEW On-gage help explains menu items at the touch of a button
RESET feature instantly restores factory settings
Durable
NEW Weatherproof, dustproof, and water-resistant—IP65-rated enclosure
Rugged indoor/outdoor instrument—ideal for field or shop use
NEW Ergonomic design with durable rubberized grip
Shock-absorbing, protective rubber holster for added impact resistance
Two year warranty on gage body AND probe
Accurate
Produces a more accurate peak-to-valley height measurement. See linearized peak height (HL)
Certificate of Calibration showing traceability to PTB included (Long Form)
Conforms to national and international standards including ISO 8503-5, ASTM D4417 Method C, NACE RP0287 and SSPC-PA17
Versatile
PosiTector body accepts all PosiTector RTR, SPG, 6000, 200, DPM, IRT, SST, SHD, BHI, and UTG probes easily converting from a surface profile gage to a coating thickness gage, dew point meter, soluble salt tester, hardness tester, or ultrasonic wall thickness gage
Mils/Microns switchable
Selectable display languages
NEW Auto rotating display with Flip Lock
Standard Models
Includes ALL features as shown on left plus...
NEW Storage of 1,000 readings per probe—stored readings can be viewed or downloaded
Powerful
Statistics mode continually displays/updates average, standard deviation, min/max, and number of readings while measuring
NEW Screen Capture—save 100 screen images for record keeping and review
NEW Instant-on feature quickly powers up the gage if recently powered down
NEW Up to 30% longer battery life
USB port for fast, simple connection to a PC and to supply continuous power. USB cable included
PosiSoft USB Drive—stored readings and graphs can be accessed using universal PC/Mac web browsers or file explorers. No software required.
Every stored measurement is date and time stamped
Software Solutions for viewing, analyzing & reporting data
Software Updates via web keep your gage current
LFC is the authorized distributor for DeFelsko in Singapore and Indonesia. Contact us to purchase the PosiTector RTR H or any other DeFelsko products.
How to use the PosiTector RTR H?
Step 1: Preparation of both the surface to be tested and the PosiTector RTR H are necessary before performing the test.
To prepare surface:
Use cleaning putty to remove dust, debris, or residual blast media from the measurement site by firmly pressing the putty onto surface to be tested using your fingers and remove
To prepare the PosiTector RTR H:
Clean anvils using included cleaning card. Swipe card through opening a few times while firmly pressing both probe buttons to remove dust
Zero probe and verify accuracy with included shim
Ensure correct grade of replica tape is displayed in upper left hand corner of LCD
Step 2: Burnish the Testex Press-O-Film™ replica tape onto the steel surface to form an impression/reverse replica.
Testex Press-O-Film™ replica tape consists of a layer of compressible foam affixed to an incompressible polyester film of highly uniform thickness. When pressed against a roughened steel surface, the foam forms an impression, or reverse replica, of the surface.
Select appropriate grade of replica tape based on target profile
Pull a single adhesive-backed replica tape free of its release paper and apply to blasted surface
Firmly compress replica film using the rounded end of the included stainless steel burnishing tool. Apply sufficient pressure in a circular and x-y rubbing motion for 30-60 seconds to fully compress all parts of the film. In general, too much compression is safer than too little.
When complete, remove replica tape from surface
Step 3: Measure the Tape with the PosiTector RTR H
Placing the compressed tape (replica) into the PosiTector RTR H gives a measure of the average maximum peak-to-valley height of the surface roughness profile.
Insert the burnished replica tape into the measurement opening. Ensure the tape is properly positioned so that the burnished region is centered within the opening in the probe with the adhesive (sticky) side down.
To position the tape, move the Testex™ Press-O-Film™ replica tape to the back of the probe and align the two dots (printed on replica tape) with arrows on both sides of the measurement opening.
Once positioned, firmly press both probe buttons simultaneously and hold until the PosiTector RTR H beeps and the measurement is displayed.
The gage automatically subtracts the thickness of the polyester substrate from all measurements.
DeFelsko
isbn:1020-DeFelsko
Surface Roughness Tester 5 Surface Roughness Tester New